Powerware 9390 UPS (40-160kVA)

Designed to meet the current and future power protection requirements of data centers, manufacturing operations, medical facilities and other large-system applications, the Powerware 9390 provides the most robust combination of power performance, battery management, scalable architecture, flexibility, power density, and warranty and service.

That's why Eaton has conducted extensive customer research to help create a UPS that would set the pace for three-phase power protection. The result is a UPS that combines technical innovation with a rich feature set to provide a best-in-class power protection solution.
 
Built upon 40 years of power management experience, performance and continuous innovation, the Powerware 9390 provides the best combination of power performance, battery management, scalable architecture, flexibility, power density, and warranty and service.

Please contact us to discuss your requirement.

Product Summary

Technology: Series 9 (double conversion online)

Power Rating: 40-160 kVA

Voltage: 400V Three-phase in/Three-phase out

Backup time: Typical 10 mins (extendable up to several hours)

Features

  • Double-conversion design offers the highest protection possible.
  • Enables remote monitoring of the UPS and battery system.
  • Extends battery life and optimizes battery recharge time via patented ABM® technology.
  • Front-panel access for all services and operation increases serviceability and reduces repair time.
  • High efficiency of 94 percent reduces total cost of ownership by reducing cost of power to support protected loads.
  • Input power factor of 0.99 minimizes auxiliary generator sizing requirements and provides more power to unity power factor servers.
  • Integrated battery management system tests and monitors battery health.
  • Low total input harmonic current distortion (THD) of less than 5 percent enhances compatibility with upstream power systems, especially generators.
  • Optional temperature-compensated charging monitors battery temperature and extends battery life.
  • Output power rated at 0.9 power factor accommodates high power factor load requirements.
  • Reduces installation time and costs with small footprint and flexibility to install against walls, using top- or bottom-entry cabling.
  • Up to four (4) UPS modules can be paralleled with a tie cabinet, while a total of eight (8) modules can be paralleled (providing a total capacity of 1280 kVA) at a maximum.
  • Utilizes Powerware's Hot Sync® technology to parallel for capacity and redundancy.